2021/12/8 · Filename sockets and boiler labels.jpg File size 83.5 KB Dimensions 972px x 606pxGet Price
2018/10/24 · The current setup is an old electric boiler, theres no gas supply to the property so it will cost appro £800 to connect it to the mains, the install gas boiler and cooker. Buy a new electric boiler ideally one that is able to heat water on demand like a combi boiler. 1. New modern electric boiler. 2.Get Price
2011/9/21 · Thermolec Electric Boiler Wiring. I have a few questions about the power supply wiring for a Thermolec boiler. It is a TH-600-D model B-18U-FFB and is 18KW. This is a dual mode boiler, however, I only plan on using electric. I do not have or plan to have a gas/oil boiler as a backup. There are "two" breakers in the panel, one 60 amp, one 50 amp.Get Price
2019/9/3 · Hi Cat I too have an Aztec Trianco 12 kw electric boiler as well as a Potterton Gold 12 kw electric boiler with a 150 ml cylinder and have experienced same problems. Mine resulted from dodgy wiring by a very dodgy builder. I have been told that the faulty wiring has Get Price
2021/10/11 · But the 40 gallon cylinder did give hot water enough for a bath without need for electric, as did the non combi boiler, not however with the combi boiler. But with sons narrow boat we expected times with no 230 volt power, so boiler was 12 volt powered as were the pumps, so it would depend how often power is lost as to if loss of power is a real problem.Get Price
2015/1/29 · Catch 22 this one. If the rads are undersized and the building too cold, the plumber will blame the electric boiler and the electrician who supplied it. I would ask him for his heat load in writing before choosing a boiler. You also need to ensure the electrical supply isGet Price
2016/5/9 · Electric boilers can also be used for underfloor heating circuits but you need to use a thermostatic mixing valve like our Yorhe TMV3 in either 15mm or 22mm. Potterton Gold Electric 4kW – 13,600 Btu – This is not that popular due to its output but it will easily power a few rads and is ideal for a small granny annex.Get Price
2008/10/19 · I need to down rate a Fifos 9kw electric boiler for central heating and hotwater (model - XA0051/9UB) TO 6KW. I was given the boiler and, considering the price of gas, it seems a shame not to use it. The problem is, the existing supply is only 6mm2 and local rules and regulations wont let me connect a 9kw load to it.Get Price
2021/11/17 · Hi We have client that has supplied us with one of these electric boilers. After completing the install we are now having trouble wiring the time clock. We have a dryton LP111 timeclock and a RTS8 combi stat. Has anyone had any experience wiring these boilers. Could you post a diagram or someGet Price
2019/11/9 · Electric boilers, and even worse electric combi's are very electricity hungry. If you had an electric boiler and a big electric shower you'd need a big electricity supply to match. Fit a big electric shower and it'll also be massively dependant on cold mains pressure / flow rate.Get Price
2005/5/25 · An electric boiler is totally reliant on a continuing and generous electricity supply. Oil may be stored against shortages, and the modest electricity requirements of an oil boiler are easily supplied from a battery and inverter or a small generator in case of power cuts. Top : Bottom. 22 August 2016 08:47 pm.Get Price
2021/11/8 · Multiply the heating kwh by the current price of electricity, around 16p. 1e. The result will be a rough estimate of the cost of running an electric combi if it had the same power as your existing gas boiler. 1f. Cost may be a bit less if you continue to shower for the same amount of time, but at much lower flow rates.Get Price
2015/1/4 · It states the "RCD" value for this device should be 63A. I rather suspect that should be the MCB value. SO a nice meaty 16mm² cable from a switch fuse will do it. re. Mike2007 said: ↑. What if the boiler was operational on E7 during the night at …Get Price
2015/12/12 · Electric hot water cylinder is quite simple - timer/controller and a heating element, so very little to go wrong. An electrician, or a multi skilled plumber should be able to look after the controller, element, thermostat. I think you'd be better putting your premiums into a savings pot to draw on if you need them. 0.Get Price
2018/7/10 · I am an electrician and install boilers.. lol No requirement as Murdoch says but if it was my house, it was easy, and i had a RCBO board, then definitly i would give it a dedicated cct. Boilers often have zone valves, boilers also often leak, when i am fault finding a tripping RCD, boilers like outside lights and outside sockets are well up there as potential culprits.Get Price
2012/9/26 · 2,741. Sep 26, 2012. #8. It's really a case of following manufacturers instructions here if it's not obvious. If the cable enters a cool part of the boiler and terminates away from any heat source, then it's unlikely that it will need to be heat-res. Reply to 10-12 kw electric boiler in the Electrical Forum area at ElectriciansForums.net.Get Price
Heatrae Electromax is the combination of an electric flow boiler with a hot water storage cylinder and a pre-plumbed, factory fitted circulating pump. Electromax can provide wet central heating and a hot water supply, both at the same time if required, with only a Get Price
2021/10/11 · 882. Oct 23, 2021. #4. I have fitted several over the years, no gas in our village! Last one I did was 10.8 kw, the 3 bed average size property was heavily insulated and would be up to 22deg in approximately 20mins or so from about 11degrees. Once warm it needed very few cycles of the system to keep the temperature consistent.Get Price
Electric Boilers / Electric Central Heating Boilers - 0 Get Price
2012/6/2 · Reply to 12 KW Electric Boiler in the Electrical Forum area at ElectriciansForums.net Similar Threads E 3 phase boiler install on domestic property Hi all, A customer is looking into the option of upgrading to a 3 phase power supply in order to get a new electric Get Price
2021/7/8 · What a load of old Tosh. What is the purpose of the report - safety or function - what about water temperature and the Legionaire test. The 12.6A is the 3KW elemant possibly of an immersion heater or tea urn. Even the most basic electric boiler the intantaneous shower requires 6KW and a full house electric boiler requires 18-24KW.Get Price
2021/11/28 · Post thread. Questions and plumbing advice in the Central Heating Forum - Discuss all aspects of Central Heating Systems in this forum. Central Heating Systems Forum. Our forum is also known as the Boiler Forum, or Boiler Forum UK. If you're searching for the electrical aspects of Central Heating Systems then please visit the Electrical Forum ..Get Price
2006/12/11 · I am currently carrying out remedial works after an electrical fire. The cause was a loose termination at the main fuse which was feeding a GEC Nightstore 100 boiler. I had to double take when i read the spec, 19.3 KW The house has a 3 phase supply on a TT system. The house has a 3 phase supply on a TT system.Get Price
2015/1/4 · How on earth could one achieve that - if it really is a 'simple' 12kW boiler, then it will inevitably take double that current, no matter what the time of day/night. As everyone has asked, what exactly is this '12kW boiler', and is there any facility (e.g. multiple switchedGet Price
Electric Boilers / Electric Central Heating Boilers - 0 Get Price
2010/1/2 · Posts: 8055. Joined: 18 April 2006. "Trust me, the boiler will be very unhappy below about 210V and the manufacturer will wash his hands if a problem occurs. There have been several very nasty and expensive claims when the electrician ignored sound advice and didn't ascertain the total on load volt drop".Get Price
Also, is the stated 12 kw at 240 volts, or at 230 volts. Aug '21 Copy Link Andy65 9 Posts Hi Zoom, At risk of jumping off track a little, here is my anecdotal evidence base on my experience of electrical boilers. I feel it ties in with other recent discussions about Get Price
2007/12/16 · Trianco Aztec 12kw Heating Boiler. 2 posts • Page 1 of 1. by chris115 » Sun Dec 16, 2007 4:14 pm. Hello Forum - hope someone can help me. I have recently had installed a Trianco Aztec 12kw electric boiler by a Corgi Engineer (not an electrician). First Q. is would this invalidate my guarantee from Trianco who advise that the boiler is Get Price
2021/11/8 · Multiply the heating kwh by the current price of electricity, around 16p. 1e. The result will be a rough estimate of the cost of running an electric combi if it had the same power as your existing gas boiler. 1f. Cost may be a bit less if you continue to shower for the same amount of time, but at much lower flow rates.Get Price
2015/1/21 · Canadian Electrical Forum Electric Boiler Feed CEC Jump to Latest Follow 1 - 20 of 21 Posts 1 2 Next 1 of 2 Go to page Go 0 05reverb · Registered Joined Sep 27, 2011 · 4 Posts Discussion Starter · #1 · Jan 18, 2015 Only show this user Get Price
Electric Boilers / Electric Central Heating Boilers - 0 Get Price
2012/12/5 · Surrey. Country: regardless off the ins and outs off the situation your heating supplied by electric will cost around 3 times the price over gas for the same kwh. in other words gas will cost 4-5p per kw but electric will cost 12-16p per unit. so may be cheaper to bite the bulit.Get Price
2012/5/8 · 8 May 2012 at 10:32AM edited 8 May 2012 at 10:34AM. You have an electric boiler which has an output of 12kW, this passes hot water to your CH circuit and hot water tank. If you start it from cold and it's running full bore throughout then it will use around 36 kWh in 3 hours-so 22 kWh's in 3 hours is perfectly reasonable.Get Price
2012/1/25 · just been asked to connect up a 12kw electric combi boiler. run is about 13mm through floorboards. dont want to sound stupid but does this have to be 16mm Commercial Electrical Forum Industrial Electrical Forum Electrical Engineering Forum Alarms and CCTV (Public) Alarms and CCTV (Private)Get Price
Electric Boilers / Electric Central Heating Boilers - 0 Get Price
2005/5/25 · An electric boiler is totally reliant on a continuing and generous electricity supply. Oil may be stored against shortages, and the modest electricity requirements of an oil boiler are easily supplied from a battery and inverter or a small generator in case of power cuts. Top : Bottom. 22 August 2016 08:47 pm.Get Price
Amptec Electric Flow Boiler Series Heatrae Sadia The Amptec range of electric flow boilers have been designed to be compatible with standard radiators, underfloor heating, circulating pumps, programmers, room thermostats and thermostatic radiator valves. They Get Price
2011/9/5 · Both boilers will only provide as much heat as required, using as much electricity or gas as required. Gas isn't always that much cheaper than economy rate electric. It'd be useful if you said what rates you're paying for power during the economy 10 periods.Get Price
I am starting from scratch in a cavernous 1870's brick house, with solid brick walls. My thought was to install cast iron rads with a TRV in each room powered by an electric boiler such as Electro (Nat gas not available) However, the electrician is urging me to forget Get Price